Multi-line 2 ASC Application Software series 4.x 4.24.0
Multi-line 2 ASC Application Software series 4.x 4.24.0
You have chosen to download our software.
Within a few seconds, you will receive an email containing a download link.
Having trouble using the software? Please contact support@deif.com.
Best regards,
DEIF A/S
The software is subject to copyright DEIF A/S
By following the above mentioned link and downloading the file you automatically accept DEIF A/S copyright and license agreement (EULA). The license agreement can be found on www.deif.com/software
- ASC-4 Battery - Automatic Sustainable Controller
- ASC-4 Solar - Automatic sustainable controller
- ASC-4 Battery Standalone - Automatic sustainable controller
4.24.0
PM compatibility version 1.28.0
New features:
- Support for Matter Energy PV protocol added.
- PMS Mode update feature added to ASC-4 Solar and Battery.
- A battery will now automatically charge to keep connected gensets at the min. DG load set point in island operation as long DG charging is enabled and SOC is below SOC maximum.
- Batteries can now automatically charge to assist the plant in reaching required mains set points if enabled by parameter 8025 and mains charging is also enabled.
- Support for Matter Energy PCS protocol added.
- Support for INVT XG Series PV protocol added.
- Inverter and busbar V/f measurements from inverter communication supported on all protocols on ASC-4 Solar and ASC-4 Battery.
- Support for SolarEdge PPC PV protocol added.
- New display view line for displaying ESS Power mode added.
Changes:
- Updated Allspark BMS protocol to use the read DC output voltage for calculating maximum charge capacity.
- Updated Schneider CL 30/33/50/60 PV protocol to only read 6 DC string current values to be compatible with the newest Schneider firmware.
- Updated Huawei V.3 PV Protocol to send a start/stop command to the inverter based on the ASC status.
Corrections:
- Corrected issue where multiple batteries operating in island with PVs could cause the PVs to overproduce power compared to what the batteries was asked to charge.
- Corrected issue where parameter 2741 for delaying regulation after start signal did not work for charging set points.
4.24.0 |
24/11/2022 |
PM compatibility version 1.28.0 New features:
Changes:
Corrections:
|
4.29.0 |
10/01/2025 |
PM compatibility version 1.35.1 New features
Changes
Corrections
|
4.28.0 |
22/05/2024 |
PM compatibility version 1.33.0 New features 1- Added support for the Acrel ADL power meter protocol. Changes 1- Updated the sequence of grid mode switching in the Sinexcel PWS1 ESS protocol. It will now always use the VSG modes as intermediate modes, in between the required grid modes, to prevent the PCS from stopping. Corrections: 1- Corrected issue where the Megarevo MPS ESS protocol would reinitialize the start sequence of the PCS in a loop. |
4.27.2 |
01/03/2024 |
PM compatibility version 1.33.0 Corrections:
|
4.27.0 |
19/12/2023 |
PM compatibility version 1.33.0 New features:• Added support for using CAT EMCP 4 controllers directly as power meter.
Changes:• Updated the Ausar ESS protocol to make more data available and acknowledge faults in the system when the "ESS shutdown" alarm is acknowledged.
Corrections.• Split the "Secure Elite XXX" power meter into two protocols: "Secure Elite 100/300" and "Secure Elite 440/500". This was done to correct a power scaling issue. |
4.26.1 |
26/10/2023 |
PM compatibility version 1.30.0
Corrections
|
4.26.0 |
10/07/2023 |
PM compatibility version 1.30.0 New features
Changes
Corrections
|
4.25.0 |
09/02/2023 |
PM compatibility version 1.29.0 New features:
Changes:
Corrections:
|
4.24.0 |
24/11/2022 |
PM compatibility version 1.28.0 New features:
Changes:
Corrections:
|
4.23.1 |
15/09/2022 |
PM compatibility version 1.25.0 Corrections:
|
4.23.0 |
31/08/2022 |
PM compatibility version 1.25.0 New features:
Changes:
Corrections:
|
4.22.0 |
03/05/2022 |
PM compatibility version 1.25.0 New features:
Changes:
Corrections:
|
4.21.0 |
18/02/2022 |
PM compatibility version 1.25.0 New features: Changes: |
4.20.0 |
09/12/2021 |
PM compatibility version 1.24.2 New features:1- Sungrow LC100 BCU protocol added. Changes:1- Renamed "Ginlong Solis" PV protocol to "Solis (Ginlong)". |
4.19.0 |
22/11/2021 |
PM compatibility version 1.24.2 New features:
Changes:
Corrections:
|
4.18.0 |
20/09/2021 |
PM compatibility version 1.24.1 New features:
Changes:
Corrections:
|
4.17.1 |
16/07/2021 |
PM compatibility version 1.24.1. Corrections:1- Corrected that the EVVO PV protocol did not send control telegrams to control the active power of the inverter. |
4.17.0 |
28/06/2021 |
PM compatibility version 1.24.1. New features:
Changes:
Corrections:
|
4.16.0 |
08/04/2021 |
PM compatibility version 1.23.0. New features:
Changes:
Corrections:
|
4.15.1 |
25/02/2021 |
PM compatibility version 1.22.0. Corrections:
|
4.15.0 |
30/11/2020 |
PM compatibility version 1.22.0. New features:
|
4-14-2 |
29/10/2020 |
PM compatibility version 1.20.0 Corrections:
|
4.12.0 |
19/03/2020 |
PM compatibility version 1.16.0. New features:
|
4.11.3 |
28/01/2020 |
PM compatibility version 1.16.0 Corrections:
|
4.11.2 |
24/01/2020 |
PM compatibility version 1.16.0 Corrections:
|
4.11.1 |
31/10/2019 |
PM compatibility version 1.16.0. Corrections:
|
4.11.0 |
11/12/2018 |
PM compatibility version 1.16.0 New features:
Corrections:
|
4.10.1 |
16/04/2018 |
Corrections:
|
4.10.0 |
20/03/2018 |
PM compatibility version 1.16.0 New features:
Corrections:
|
4.05.2 |
12/01/2018 |
Corrections:
|
4.05.1 |
02/01/2018 |
PM compatibility version 1.15.0
|
4.05.0 |
30/11/2017 |
PM compatibility version 1.15.0 New features:
Corrections:
Changes:
|
4.04.0 |
05/10/2017 |
PM compatibility version 1.15.0 New features:1- Support of HiQ inverter. |
4.03.1 |
09/05/2017 |
PM compatibility version 1.15.0 Corrections:
|
4.03.0 |
03/04/2017 |
Version 4.03.0 New features:
Changes:
Corrections:
|
4.02.0 |
21/12/2016 |
PM compatibility version 1.15.0 New features:
Changes:
Corrections:
|