Multi-line 2 ALC Application Software series 4x

You’re about to download Multi-line 2 ALC Application Software series 4x

The software you are trying to download is obsolete. Please download the latest version from this page.

You have chosen to download our software.

Within a few seconds, you will receive an email containing a download link.

Having trouble using the software? Please contact support@deif.com. 

Best regards, 

DEIF A/S

The software is subject to copyright DEIF A/S
By following the above mentioned link and downloading the file you automatically accept DEIF A/S copyright and license agreement (EULA). The license agreement can be found on www.deif.com/software

This software applies to the following DEIF products:

You’re about to download 4.13.0

The main changes implemented since the last version are as follows:

PM compatibility version 1.23.1.

New features:

  • Load-groups are now able to close on a dead busbar in AUTO mode. This can be activated via Modbus commands, Modbus control register or M-Logic.
  • Eight low frequency alarms are added. These are placed in menus 1000-1070.

Changes:

  • Faster execution of load-groups closing.
  • Four output relays on terminals 118-119, 118-120, 121-122 and 123-124 are now configurable.
Ver. Date Description

4.13.0

15/06/2021

PM compatibility version 1.23.1.

New features:

  • Load-groups are now able to close on a dead busbar in AUTO mode. This can be activated via Modbus commands, Modbus control register or M-Logic.
  • Eight low frequency alarms are added. These are placed in menus 1000-1070.

Changes:

  • Faster execution of load-groups closing.
  • Four output relays on terminals 118-119, 118-120, 121-122 and 123-124 are now configurable.

4.12.0

26/11/2020

PM compatibility version 1.21.0.

New features:

  •    Configurable amount of units for triggering Fatal CAN Error alarm is added in menu 8800.

Changes:

  •    Support of ASC-4 redundancy.

Corrections:

  •    Corrected that selection of ‘Number of PMS units’ and ‘PMS CAN baud rate’ previously would only work with default settings. and an issue with redundancy.

4.11.0

13/02/2020

PM compatibility version 1.16.0
Includes version 1.15.0

New features:

  •    Now possible to open and close LG's while position failure is present.
  •    Block LG fail classes added
          • Position failure alarms set default to LG Block fail class.

Corrections:

  •    Corrected ALC Breaker Feedback Emulation.

4.10.1

10/01/2020

PM compatibility version 1.16.0

Corrections:

  •    Horn relay now working
  •    M-Logic PMS flags for GB/MB closed now working 
  •    LG(load group) pos. fail alarm now possible when LG is disabled

4.10.0

12/12/2019

PM compatibility version 1.16.0

Features:

  •    32 DG/Mains support
          • Support of 32 DG's in ID range 1-32 (AGC-4/200, version 4.65.0 required).
          • Support of 32 Mains in ID range 1-32 (AGC-4/200, version 4.65.0 required).
          • Support of 16 ASC's in ID range 25-40 (ASC-4, version 4.06.0 required).
          • Support of  8 ALC's in ID range 25-40.
  •    Support of ASC PV and Battery.
  •    Heavy Consumer logic added.
  •    Flip/Flops added to M-logic.

Changes:

  •    Disconnect Load can now be set to 200 % and 999 sec.

Corrections:

  •    Corrected: Tripped open relay hanging on redundant unit.
  •    Corrected: LG's are not opened in AUTO mode when disabled.
  •    Corrected: Digital input alarms are not activated by input.

4.00.1

29/01/2018

Corrections:

  • In some instances, all fail classes were initialised to "Shutdown" unintentionally.

4.00.0

30/10/2017

PM compatibility version 1.15.0
  
Features:
1- Includable in Power Management application type "Standard" together with AGC-4 and AGC 200.
a) Up to 16 gensets.
  b) Up to 16 mains.
c) Up to 8 BTBs/ALCs in plants.
d) Spinning reserve support.
2- Able to close and open breakers according to available power from DG. 
3- Able to place the ALC in mains load point.  

On this page, you can download software updates for your product(s) and help yourself to various utility tools and add-ons that will assist you in setting up, detecting faults and configuring your product(s).

Please be advised that not all of our products can be updated by the user. Nor do all of our products come with a utility tool. Consequently, the list on this page cannot be considered an overview of our product programme.

DEIF will register your download along with the used e-mail address for the purpose of sending out information on future updates, if requested.

DEIF cannot be made responsible for any consequences of failed product updates or use of utility tools. Nor can DEIF A/S be made responsible for consequences of changes in behaviour of products due to a software upgrade. It is always the responsibility of the user to ensure correct set-up and configuration before commissioning. Please study the version log of the software before updating the product.

Licence agreement for software downloaded from www.deif.com

Downloaded software remains the property of DEIF. The software may not be distributed for commercial purposes, changed or reused in full or in part or sold to any third parties.

The latest versions for full functionality

As always, we recommend that you install our offered improvements to fully utilise your DEIF product.

All improved software can be downloaded at your convenience at www.deif.com under “Software”.

Should you have any questions or experience problems finding the relevant software for your product, please feel free to call DEIF A/S at +45 96149614 or your relevant local DEIF office. Alternatively, we are always ready to assist you, if you send an e-mail to support@deif.com.